Problem | Cause | Solution |
---|---|---|
The Zodiac Baracuda Wahoo cleaner does not move or moves slowly. | Low water temperature, incorrect FlowKeeper Valve installation, low flow, dirty baskets/filter, damaged diaphragm, closed skimmer, air in system. | – If water is cold, increase flow to compensate for reduced hose flexibility. – Ensure FlowKeeper Valve is installed correctly with arrow pointing down. – Adjust FlowKeeper Valve to increase flow. – Clean baskets and filter. – Check diaphragm for damage or wear. – If multiple skimmers, close the one not connected to the cleaner. – Check for air in the system, secure hose connections, tighten fittings, and check the pump basket gasket. |
The Zodiac Baracuda Wahoo cleaner patterns, does not cover entire pool. | Low flow, incorrect return jet positioning, kinked hose, incorrect hose length. | – Adjust FlowKeeper Valve to increase flow to cleaner. – Ensure return fittings are directed downwards; add a return diverter if necessary. – Straighten any kinked or coiled hose. – Confirm proper hose length. |
The Zodiac Baracuda Wahoo cleaner gets stuck at steps. | Incorrect hose length, high flow, small wheel deflector. | – Confirm proper hose length and shorten if necessary. – Lower the FlowKeeper Valve setting to reduce flow. – Consider ordering a larger (16″) wheel deflector if the issue persists. |
The Zodiac Baracuda Wahoo cleaner moves extremely fast or climbs walls. | High flow, multiple skimmers not balanced. | – Lower the FlowKeeper Valve setting to reduce flow. – Open a second skimmer if there is more than one to balance the flow. |