Polaris Phenom iQ+ Troubleshooting

Polaris Phenom iQ+ Error Codes

Information about the cleaner status and any relevant condition will be displayed on the control box and/or in the iAquaLink® app.

In-App Display Solution
  • Pump Motor
  • Traction Motor Right
  • Traction Motor Left
  • Check for corrosion or bent pins in the power cable connection area.
  • Turn each wheel one quarter turn in one direction repeatedly until rotation is smooth. Repeat, turning wheels in the opposite direction until rotation is smooth.
  • If this does not resolve the problem, contact your local retailer for a diagnostic review or call customer service.
  • Pump Motor Consumption
  • Check for small debris or hair in the fan impeller.
  • Thoroughly clean the filter canister.
  • If this does not resolve the problem, contact your local retailer for a diagnostic review or call customer service.
  • Drive Motor Consumption Right
  • Drive Motor Consumption Left
  • Thoroughly clean the filter canister.
  • Turn off the cleaner and submerge. Shake to release air bubbles. Restart cycle.
  • If this does not resolve the problem, contact your local
  • retailer for a diagnostic review or call customer service
  • Cleaner Floating
  • Turn cleaner power off, then submerge cleaner according to correct procedure.
  • Cleaner Out of the Water
  • Turn off the cleaner and submerge. Shake to release air bubbles. Restart cycle.
  • N/A
  • Cleaner has completed a cleaning cycle. This is not an error. No action required.
  • Communication
  • Turn cleaner power off and on again to reset.
  • Check floating cable connection to the control box.
  • Check for corrosion or bent pins at the connection point.
  • If this does not resolve the problem, contact your local retailer for a diagnostic review or call customer service.
  • Sensor Unit
  • Contact approved service station for replacement
  • Connection Error
  • Check that the control box is plugged into a GFCI outlet and that the Wi-Fi icon is illuminated.
  • If not, go through the set-up steps to reconnect to the home router. Check that the router is in close enough range to the control box. Install a Wi-Fi extender if necessary.

The Polaris Phenom iQ+ Lights on control box flash after pressing Start/Stop

Cause Solution
  • Floating cable not connected
  • Unplug and then reconnect the floating cable to the control box.
  • Cleaner not fully submerged
  • Remove cleaner from pool and re-submerge
  • Poor connection or need to
  • Unplug the control box and reconnect to a GFCI outlet.
  • Press “Start” to begin a new cycle.
  • Propeller or wheels may be jammed and not turning correctly
  • Contact your local retailer to request a diagnostic review. If the problem is not resolved, contact Polaris Technical Support at 1-800-822-7933.

The Polaris Phenom iQ+ flashing lights appear on the control box during the cleaning cycle

Cause Solution
  • Cleaner not fully submerged
  • Remove cleaner from pool and re-submerge

The Polaris Phenom iQ+ cleaner does not stay on the pool surface or is floating excessively

Cause Solution
  • There is air trapped inside the cleaner housing
  • Remove cleaner from pool and re-submerge
  • The filter canister is full or dirty
  • Dispose of debris and thoroughly clean filter canister with mild soap and a soft brush. Then, re-submerge the cleaner

The Polaris Phenom iQ+ cleaner is not climbing walls

Cause Solution
  • The filter canister is full or dirty
  • Dispose of debris and thoroughly clean filter canister with mild soap and a soft brush. Then, re-submerge the cleaner
  • Tire treads worn down
  • See Replacing Worn Parts.
  • Confirm appropriate pool chemistry
  • Speak with your pool service professional. Do not leave cleaner in the pool during any chemical treatments.

The Polaris Phenom iQ+ cleaner is not moving

Cause Solution
  • Not supplied with electricity.
  • The outlet the control box is connected to, is not supplying electrical power. Check that the outlet to which the control box is connected is receiving electricity.
  • Cycle not started
  • Press the Start button to initiate a cleaning cycle.
  • Reset needed
  • Disconnect the unit power and reconnect after 20 seconds. If the problem is not resolved, contact your local retailer to request a diagnostic review or contact Polaris Technical Support at 1-800-822-7933.

The Polaris Phenom iQ+ floating cable has excessive tangling

Cause Solution
  • Too much cable in the water
  • Place only the required amount of cable into the water to allow it to reach the farthest end of your pool with remaining cable on the pool deck
  • Removal needed
  • Untangle the twisted cord and lay in sun to reduce memory

The Polaris Phenom iQ+ cleaner is not cleaning the pool effectively

Cause Solution
  • The filter canister is full or dirty
  • Dispose of debris and thoroughly clean filter canister with mild soap and a soft brush. Then, re-submerge the cleaner
  • Brushes are worn
  • Check the wear indicator(s)
  • Cable is excessively tangled
  • Untangle the twisted cord and lay in sun to reduce memory
I have problems with my Polaris Phenom iQ+

Most Common Polaris Phenom iQ+ Reported Problems

No categorized comments found for this post.

Technical Malfunction Issues

No value found for field: technical_malfunctions

Power and Charging Issues

No value found for field: power_and_charging

Performance Issues

No value found for field: performance

Setup and Usage Issues

No value found for field: setup_and_usage

Customer Support Issues

No value found for field: customer_support

Other Issues

No value found for field: other

Polaris Phenom iQ+ Pool Cleaner Not Working?

If you're experiencing issues with your Polaris Phenom iQ+ pool equipment, you're not alone. Many users have faced similar challenges and have shared their experiences to help others troubleshoot and resolve these problems.

Submit an Product Issue for Polaris Phenom iQ+

The maximum upload file size: 10 MB. You can upload: image. Links to YouTube, Facebook, Twitter and other services inserted in the comment text will be automatically embedded. Drop file here