Polaris Alpha Iq Error Codes
The cleaner status and any relevant condition will be displayed on the control unit and/ or in the iAquaLink™ app.
Control Unit
Display |
In-App Display |
Solution |
1
2
3
|
- Pump Motor
- Traction Motor Right
- Traction Motor Left
|
- Check for corrosion or bent pins in the power cable connection area.
- Turn each wheel one quarter turn in one direction repeatedly until rotation is smooth. Repeat, turning wheels in the opposite direction until rotation is smooth.
- If this does not resolve the problem, contact your local retailer for a diagnostic review or call customer service.
|
4
|
|
- Check for small debris or hair in the fan impeller.
- Thoroughly clean the filter canister.
- If this does not resolve the problem, contact your local retailer for a diagnostic review or call customer service.
|
5
6
|
- Drive Motor Consumption Right
- Drive Motor Consumption Left
|
- Thoroughly clean the filter canister.
- Turn off the cleaner and submerge. Shake to release air bubbles. Restart cycle.
- If this does not resolve the problem, contact your local retailer for a diagnostic review or call customer service.
|
7
|
|
- Turn cleaner power off, then submerge cleaner according to correct procedure.
|
8
|
|
- Turn off the cleaner and submerge. Shake to release air bubbles. Restart cycle.
|
9
|
|
- Cleaner has completed a cleaning cycle. This is not
an error. No action required.
|
10
|
|
- Turn cleaner power off and on again to reset.
- Check floating cable connection to the control unit.
Check for corrosion or bent pins at the connection point.
- If this does not resolve the problem, contact your local retailer for a diagnostic review or call customer service.
|
11
|
|
- Contact approved service station for replacement.
|
N/A
|
|
- Check that the control unit is plugged into a GFCI outlet and that the LAN/WEB icons on the box are illuminated.
- If not, go through the set-up steps to reconnect to the home router or press the Wi-Fi to Phone button to connect the system in 15-minute Wi-Fi to Phone mode. Check that the router is in close enough range to the control unit. Install a Wi-Fi extender if necessary.
|
The Polaris Alpha Iq Lights on control box flash after pressing Start/Stop
Cause |
Solution |
- Floating cable not connected
|
- Unplug and then reconnect the floating cable to the control box.
|
- Cleaner not fully submerged.
|
- Remove cleaner from pool and re-submerge
|
- Poor connection or need to restart cycle.
|
- Unplug the control unit and reconnect to a GFCI outlet. Press “Start” to begin a new cycle.
|
- Propeller or wheels may be jammed and not turning correctly
|
- Contact your local retailer to request a diagnostic review. If the problem is not resolved, contact Polaris Technical Support at 1-800-822-7933.
|
The Polaris Alpha Iq flashing lights appear on the control unit during the cleaning cycle.
Cause |
Solution |
- Cleaner not fully submerged
|
- Remove cleaner from pool and re-submerge.
|
The Polaris Alpha Iq cleaner does not stay on the pool surface or is floating excessively.
Cause |
Solution |
- There is air trapped inside the cleaner housing.
|
- Remove cleaner from pool and re-submerge.
|
- The filter canister is full or dirty
|
- Dispose of debris and thoroughly clean the filter canister with mild soap and a soft brush. Then, re-submerge the cleaner
|
The Polaris Alpha Iq cleaner is not climbing walls.
Cause |
Solution |
- The filter canister is full or dirty.
|
- Dispose of debris and thoroughly clean the filter canister with mild soap and a soft brush. Then, re-submerge the cleaner (see: Clean the Filter Canister).
|
|
- See: Replacing Wear Parts
|
- Confirm appropriate pool chemistry
|
- Speak with your pool service professional. Do not leave cleaner in the pool during any chemical treatments.
|
The Polaris Alpha Iq cleaner is not moving
Cause |
Solution |
- Not connected to electricity.
|
- The outlet the control unit is connected to, is not supplying electrical power. Check that the outlet to which the control unit is connected is receiving electricity.
|
|
- Press the Start button to initiate a cleaning cycle.
|
|
- Disconnect the unit power and reconnect after 20 seconds. If the problem is not resolved, contact your local retailer to request a diagnostic review or contact Polaris Technical Support at 1-800-
822-7933.
|
The Polaris Alpha Iq floating cable has excessive tangling
Cause |
Solution |
- Too much cable in the water.
|
- Place only the required amount of cable into the water to allow it to reach the farthest end of your pool with remaining cable on the pool deck. (See: Install and Submerge the Cleaner)
|
|
- Untangle the twisted cord and lay in sun to reduce memory. (See: Cord Tangling).
|
The Polaris Alpha Iq cleaner is not cleaning the pool effectively.
Cause |
Solution |
- Filter canister is full or dirty
|
- Dispose of debris and thoroughly clean the filter canister with mild soap and a soft brush. Then, re-submerge the cleaner
|
|
- Check the wear indicator(s)
|
- Cable is excessively tangled
|
- Untangle the twisted cord and lay in sun to reduce memory.
|
Shows auto code on display and Bluetooth light is flashing?
Why?
Submit Your Own IssueMy Alpha iq vacuum I believe it shows a error code,
Submit Your Own IssueThe third mode does not work, (walls, floor, top) all other modes work.
Any thoughts why not working?